Reading time: 2 minutes
- Residential Buildings- dwelling houses, hotels, hostels, boiler rooms and plant rooms, garages etc.
- Educational buildings
- Institutional buildings
- Assembly buildings
- Business and office buildings
- Mercantile buildings
- Industrial buildings
- Storage Rooms

Following are the live loads for different buildings:
Sl. No. |
Description |
UDL Load (kN/m2) |
Concentrated Load (kN) |
1. |
Bathrooms and toilets in all types of buildings |
2 |
1.8 |
2. |
Living and bed rooms |
||
3 |
Office rooms in |
||
(i) Hostel, hotels, hospitals and business building with separate store |
2.5 |
2.7 |
|
(ii) In assembly buildings |
3 |
4.5 |
|
4. |
Kitchens in |
||
(i) Dwelling houses |
2 |
1.8 |
|
(ii) Hostels, hotels and hospitals |
3 |
4.5 |
|
5. |
Banking halls, class rooms, X-ray rooms, operation rooms |
3 |
4.5 |
6. |
Dining rooms in |
||
(i) Educational buildings, institutional and mercantile buildings |
3 |
2.7 |
|
(ii) Hostels and hotels |
4 |
2.7 |
|
7. |
Corridors, passages, stair cases in |
||
(i) Dwelling houses, hotels, and hostels |
3 |
4.5 |
|
(ii) Educational, institutional and assembly buildings |
4 |
4.5 |
|
(iii) Mercantile buildings |
5 |
4.5 |
|
8. |
Reading rooms in libraries |
||
(i) With separate storage |
3 |
4.5 |
|
(ii) Without separate storage |
4 |
4.5 |
|
9. |
Assembly areas in assembly buildings |
||
(i) With fixed seats |
5 |
||
(ii) Without fixed seats |
5 |
3.6 |
|
10. |
Store rooms in educational buildings |
5 |
4.5 |
11. |
Store room in libraries |
6 for a height of 2.24 2kN/m2 for every 1m additional height |
4.5 |
12. |
Boiler rooms and plant rooms in |
||
(i) Hostels, hotels and hospitals, mercantile and industrial buildings |
5 |
4.5 |
|
(ii) Assembly and storage buildings |
7.5 |
4.5 |
Read More: Floors Functional Requirements in Building Construction