Reinforced concrete slab design and detailing guidelines for depth of slab, loads on slab, reinforcement guide for one-way and two-way slabs as per IS 456:2000 have been tried to present here. Following are the RCC Slab Design and Detailing guidelines: ...
Design Guide
Home/How To Guide/Design Guide/Page 4Do you need to remove the ads? Become VIP Member
Discy Latest Articles
Types of Design and Detailing Errors in Construction and their Prevention
Common design and detailing errors in construction arises due to either inadequate structural design or due to lack of attention to relatively minor design details. Types of Design and Detailing Errors in Construction and their Prevention Following are the different ...
Isolated Footing Design Example and Excel Sheet
Isolated footing design example with step by step procedure and isolated footing design excel sheet (spreadsheet) is also provided for easy and fast calculation. Learning design with examples is always the best method of learning. Step by step procedure for ...
Isolated Footing Design Guidelines and Specifications as per IS 456: 2000
Specifications for Design of footings as per IS 456: 2000 Isolated footings are designed to sustain the applied loads, moments and forces and the induced reactions and to ensure that any settlement which may occur is as nearly uniform as ...
Different Failure Modes of Concrete Columns – Compression Members
There are three modes of failure of concrete columns (compression members) i.e. failure due to pure compression, combined compression and elastic instability. These modes of failures of concrete compression members are discussed.
Design of Rectangular Reinforced Concrete Beam
Reinforced concrete beams are structural elements that designed to carry transverse external loads. The loads cause bending moment, shear forces and in some cases torsion across their length. Moreover, concrete is strong in compression and very weak in tension. Thus, ...
Design of Raft Foundations – Methods and Calculations
Design of Raft Foundations – Methods and Calculations According to IS – 2950:1965, the design criteria of raft footings are given below: The maximum differential settlement in foundation on clayey soils and sandy soils should not exceed 40mm and 25mm ...
DESIGN STEPS OF RCC MEMBER FOR SHEAR AND TORSION
Design of a reinforced concrete section for shear is carried on in the following steps: (a) Determine nominal shear stress of concrete by using following formula: (b) Determine design shear strength of concrete, (Table 1 below). Table-1: Design Shear Strength ...