Many factors affects the depth of foundation. such as type of soil, ground water table, loads from structure, bearing capacity and density of soil and other factors. The minimum depth of foundation is calculated by Rankine’s formula when the bearing ...
Foundation
Home/Foundation/Page 9Do you need to remove the ads? Become VIP Member
Discy Latest Articles
Design of Reinforced Concrete Footings: ACI 318-14 and IS456
Reinforced concrete footing are designed based on column loads and moments at base and the soil data. This article shed light on the design of reinforced concrete footing. Reinforced concrete footing types Following are the types of foundations in order ...
Pile Load Capacity Calculation – Single Pile and Group Pile
The Pile load capacity calculation will determine the ultimate load the pile foundation can take under service load condition. This capacity is also called as bearing capacity of piles. The piles installed can be a single pile or group piles. ...
Methods of Concreting of Columns, Pedestals and Footings
Proper concreting of reinforced concrete columns, pedestals and footings is needed to ensure desired strength and durability of these structural members. Improper method of concreting may lead to corrosion of steel reinforcement due to pores, cracks in concrete and concrete ...
Load Test on Piles – Methods of Pile Load Test
Load tests on piles are conducted on completion of 28 days after casting of piles. Two types of tests namely initial and routine tests, for each type of loading viz. vertical, horizontal (lateral) pull out, are performed on piles. Initial ...
Isolated Footing Design Guidelines and Specifications as per IS 456: 2000
Specifications for Design of footings as per IS 456: 2000 Isolated footings are designed to sustain the applied loads, moments and forces and the induced reactions and to ensure that any settlement which may occur is as nearly uniform as ...
Balanced Footings and Cantilever Footings
Balanced and Cantilever Footings A balanced footing which is also called as strap footings consists of two separate footings connected by a strap beam. Balanced footing is required where the one of the footing has limited space for bearing, or ...
FOUNDATIONS & ANCHORAGE FOR PRE-ENGINEERED BUILDING
Foundation design and construction for Pre-Engineered Buildings are important to the assembly process. To ensure optimum integrity of new building, the foundation must meet certain design criteria and load conditions. It is required that all building foundations be designed by ...