There are various causes for various types of cracks in masonry buildings such as in walls, foundations, slabs, columns. Repair methods of such cracks in masonry buildings is discussed. There are certain problems in structures that arise suddenly. Some problems like crack formation or settlement of foundation won't give a caution before it appears. Most of these problems arise due to improper construction method and carelessness during initial construction. So, care during initial stages can help avoid such problems that require huge maintenance.Contents:
Causes and Types of Cracks in Masonry Buildings and their Repair Methods
The cracks appear in the masonry structure, at a certain period of time. Most commonly caused cracks with their respective causes and precaution, are explained below:Cracks in Brick Mortar Joints
Vertical or horizontal cracks are seen at the brick mortar joints. One of the main reason is the sulfate attack, that weakens the mortar. These cracks mainly appear after 2 to 3 years of construction. These cracks can be avoided by:- Checking the sulfate content of bricks used in construction
- The damping of brick wall has to avoided, as these are more prone to sulfate attack when it is damp
Fig.1: Cracks Formed in the Brick Mortar Joints
Crack Formation Below the Load Bearing Walls
Cracks are observed below the load bearing walls, mainly those that supports R.C.C slabs. Now the temperature variation makes the reinforced concrete slab to expand or contract, but both in the horizontal direction. These are observed in the Top most story that is more exposed to the temperature changes. There no smooth contact between the wall and the slab. Hence the frictional forces are developed at the contact place of the wall and the slab. This creates cracking in the walls. The precaution that can be suggested is to provide a bearing plaster over the brick wall, which helps in having a smooth contact with the floor over it. If required a bituminous coating can be applied over the plaster applied.Fig.2: Cracks in Masonry Walls of Multi-Storey Building at Higher Floors
Main Wall and Cross Walls Joint Cracks
Improper bonding between the cross wall and the main wall creates cracks between the joints. This suggests us to have proper and quality bonding between the two walls. These are properly done by toothing.Fig.3: Shear Cracks between Cross Wall and the Main Long Wall of Masonry Building
Fig.4: Tooth connection between the Walls
Cracks Found in R.C.C Columns and Masonry
One of the main reason behind this is the differential movement of the columns and the masonry because of temperature variation. This variation can be either expansion or contraction depending upon the temperature. These cracks can be hidden by making a groove in the reinforced concrete column and masonry junction. The provision of chicken wire alternatively at the plaster between the junction of columns and masonry can also help in this variation.The Horizontal cracks between R.C.C slab and the brick parapet
The non-projecting slab is mainly subjected to such cracks. This too is due to the temperature variation and the drying shrinkage. Small micro cracks formed he propagated with the increase in expansion or contraction. These cracks can be hidden by making a groove at the masonry junction will help in hiding the cracks. The provision of chicken wire alternatively at the plaster junction can also help.Cracks in Roof Slab
The exposure of roof slab to higher temperature variation cause cracks numerously. This can be reduced by providing a weather proof course. New treatment methods and compounds are available as weather course, that is applied over the terrace.Repair Methods for Cracks in Masonry Building Structural Members
Measures to be followed for already appeared cracks are:- Application of grouting or uniting for cracks that are appeared in the main structural members, that cannot be compromised at any cost. The material mainly used for this is either cement or epoxy mixture. The epoxy has the ability to fill even small and thin cracks, say as fine as 0.1mm. These epoxy gain high strength and adhesion.
- The flexible sealant can be used for cracks that are appeared on the non-structural members. This helps in having a control over the differential movement (expansion or contraction) of the member under temperature changes.
- Epoxy putty, polymer filler or lime cement mortar can be used for filling the cracks seen in plain cement concrete.
Measures for Foundation Settlement
The unequal settlement of foundation due to the variation of bearing capacity at different points of the building result in the formation of cracks in the building. The Certain preventive measure is:- The foundation is planned to lay or hard soil
- Gradual raising of foundation and wall has to be made, for letting the structure to have an allowable settlement.
- The settlement value of should not go beyond allowable, under any combination of loads.
- The foundation designed should facilitate uniformly distributed pressure on the soil.