Adjusting the slump of concrete is a part of the concreting process, which the contractors should manage properly and cautiously. The concrete slump variation from one transit mixer to another is generally due to aggregate moisture content, concrete temperature, mixing ...
Material Testing Guide
Home/How To Guide/Material Testing GuideDo you need to remove the ads? Become VIP Member
Discy Latest Articles
How to Carry out Concrete Cubes Sampling as per IS 456?
The compressive strength test is one of the most important tests performed on concrete. This test gives a fair idea about the quality of the concrete that is being poured at the site. While conducting this test, the major question ...
How to Test Reinforced Concrete Structures for Watertightness?
A watertightness test is conducted on water-containment structures to check whether undetected and incidental defects are leading to leakage of water. The types of linings used in a water-containment structure, their location (semiarid or arid area, covered or not), and ...
How to Measure the Rate of Water Absorption by Hydraulic Cement Concrete?
The water absorption test determines the water absorption rate (sorptivity) of both the outer and inner concrete surfaces. The test involves the measurement of the increase of mass of concrete samples resulting from the absorption of water as a function of ...
How to Test Hardness of Building Materials?
The hardness of a material is defined as the resistance of that material to an indentation or plastic deformation. Hardness is hence a measure of the resistance of the material towards abrasion, cutting, and scratching. Hardness test is commonly used ...
Failed Concrete Slump Test? Here is What you Should do
Engineers should make a proper decision when an on-site slump test fails. The decision could be an outright rejection of the complete batch of concrete or the suspension of the work due to the contractor’s failure to follow project requirements. ...
How to Test the Temperature of Fresh Concrete as per ASTM?
The temperature of fresh concrete can be determined as per ASTM C1064 to ensure the concrete’s conformity with standard temperature specifications. The method employs a calibrated thermometer to test the concrete temperature. The temperature of the concrete affects the way ...
What to Do if Concrete Cylinder Test Fails at 28 Days?
The failure of the concrete cylinder test at 28 days occurs due to several factors like improper casing and curing of specimens and an incorrect mix of concrete used for construction. The cause of the failure should be identified by ...