How to calculate length of overlap for reinforcement steel?
If the wall is rigid and cannot be move when the pressure exerted on the wall, then the soil behind the wall is in the state of static equilibrium. This case is called rest earth pressure. For bridges, slab walls and Abutments is soil mass or backfill with static equilibrium is required because it cRead more
If the wall is rigid and cannot be move when the pressure exerted on the wall, then the soil behind the wall is in the state of static equilibrium. This case is called rest earth pressure.
For bridges, slab walls and Abutments is soil mass or backfill with static equilibrium is required because it can bear the heavy load. Thus for safety point of view in construction pressure at rest is considered. In this case, all the pressures are being exerted uniformly on the retaining wall.
There are two types of conditions developed
For normally consolidated clay,
K= 1- sin(¢)
For overconsolidated clay
K(overconsolidated )= K(normally consolidated clay) x √OCR
OCR= OVERCONSOLIDATION RATIO
See less
Gopal Mishra
Lapping of reinforcement is usually done where minimum bending stress is required. In general, lap length is 50d which means 50 times the bar diameter is provided if both bars are of same diameter. Lap length in tension: The lap length including anchorage value of hooks shall be For flexural tensionRead more
Lapping of reinforcement is usually done where minimum bending stress is required. In general, lap length is 50d which means 50 times the bar diameter is provided if both bars are of same diameter.
Lap length in tension:
The lap length including anchorage value of hooks shall be
For flexural tension – Ld or 30d whichever is greater is considered.
For direct tension – 2Ld or 30d whichever is greater is considered.
The straight length of lapping of bars shall not be less than 15d or 20cm.
Lap Length in Compression:
The lap length is equal to the development length calculated in compression but not less than 24d.
For Different Diameter Bars:
See lessWhen the bars of different diameters are to be spliced, the lap length is calculated considering the smaller diameter bar.